基于比值法的地表反射率测量系统研究

侯志宽1,2,张艳娜1,李 新1,刘恩超1*,张 权1,徐海东1,2,郑小兵1   

  1. 1中国科学院安徽光学精密机械研究所,中国科学院通用光学定标与表征技术重点实验室,安徽 合肥 230031; 2 中国科学技术大学,安徽 合肥 230026
  • 出版日期:2019-09-28 发布日期:2019-09-18
  • 作者简介:侯志宽(1992-),山东枣庄人,研究生,主要从事光电仪器技术和光学辐射定标方面的研究。 E-mail:hoo@mail.ustc.edu.cn
  • 基金资助:
    Supported by Youth Project of National Natural Science Foundation of China (国家自然科学基金青年项目,41705013),United Foundation of Chinese Academy of Sciences(中国科学院联合基金,6141A01011602)

Research on surface reflectivity measurement system based on ratio method

HOU Zhikuan1,2, ZHANG Yanna1, LI Xin1, LIU Enchao1*, ZHANG Quan1, XU Haidong1,2, ZHENG Xiaobing1   

  1. 1 Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China; 2 University of Science and Technology of China, Hefei 230026, China
  • Published:2019-09-28 Online:2019-09-18

摘要: 为了实现地表反射率长期自动化观测,提高场地定标频次,提出了一种基于比值辐射测量的地表反射率测量方法。利用场地反射率监测辐射仪和野外光谱辐照度仪进行同步观测,获取同一时间的地表辐亮度和大气总照度,通过比值法即可直接获得地表反射率参数。设计了基于标准辐射源的实验室辐射定标,分别获取辐射计和照度仪的定标系数,进而获得基于比值法测量地表反射率的输入系统参数。在室外开展了标准板测量比对实验,在可见-近红外波段比值辐射测量结果与实验室定标后参考板方向反射率数值的相对偏差在3%以内,验证了该测量系统的有效性。

关键词: 辐射测量, 地表反射率, 辐射计, 照度仪

Abstract: In order to realize long-term automatic observation of surface reflectivity and improve the frequency of site calibration, a method of surface reflectivity measurement based on ratiometric radiation measurement is proposed. Synchronous observation is carried out by using spectally-reflect automatic spectroradiometer and hyperspectral irradiance meter. Surface radiance and total atmospheric illuminance at the same time are obtained, and the surface reflectance parameters can be obtained by the ratio method. The laboratory radiation calibration based on standard radiation source is designed to obtain the calibration coefficients of the radiometer and illuminometer respectively, and then the input system parameters based on the ratio method to measure the surface reflectivity are obtained. The standard board measurement comparison experiment is carried out outdoors. The relative deviation between the visible-near-infrared ratio radiation measurement and the reference plate reflectance value after laboratory calibration is within 3%, and the effectiveness of the measurement system is verified.

Key words: radiometry, ground reflectance, spectroradiometer, irradiance meter