| [1]NAROTAM P K, MORRISON J F, NATHOO N. Brain tissue oxygen monitoring in traumatic brain injury and major trauma: outcome analysis of a brain tissue oxygen-directed therapy[J]. Journal of Neurosurgery, 2009, 111(4): 672-82.[2]王其平,高恒,那汉荣,等. PbtO2 联合颅内压多参数监测对急性重型颅脑损伤合并多发伤目标治疗的影响[J]. 江苏医药, 2013, 39(22): 4.WANG Q P, GAO H, NA H R, et al. The influence of PbtO2 combined with multi-parameter intracranial pressure monitoring on goal-directed therapy in acute severe craniocerebral injury complicated with multiple injuries [J]. Jiangsu Medicine, 2013, 39(22): 4.[3]顾帅鹏,龚嵩,高伟. 颅内压监测在颅脑损伤中的应用进展[J]. 临床急诊杂志, 2024, 25(2): 87.GU S P, GONG S, GAO W. Progress in theApplication of Intracranial Pressure Monitoring in Traumatic Brain Injury [J]. Clinical Emergency Medicine Journal, 2024, 25(2): 87.[4]XU Z, M M Z, S K Z, et al. A new method for noninvasive venous blood oxygen detection[J]. Biomedical engineering online, 2024, 15(1): 84.[5]SCHOLL C A, WATHEN J J, FITCH M J, MILSAP G W, THOMPSON M C, VILLAFAN-DELGADO M, ODOEMENE K, EGGEBRECHT A T, MARKOW Z E, RICHTER E J, TROBAUGH J W, CULVER J P, BLODGETT D W, HENDRICKSON S M, Evaluation of neural information content from the phase component of a 32-channel frequency-domain fNIRS systemm [C]Proceedings of SPIE 11629, Optical Techniques in Neurosurgery, Neurophotonics, and Optogenetics. SPIE, 2021: 116292I.[6]ZHANG Q, BRUKILACCHIO T J, Li A, STOTT J J, CHAVES T, HILLMAN E, WU T, CHORLTON M, RAFFERTY E, MOORE R H, KOPANS D B, and BOAS D A, Coregistered tomographic x-ray and optical breast imaging: initial results, J. Biomed. Opt. 10(2),2005: 024033. [7]W H Z, L T Q, F G T, et al. Affective or cognitive interpersonal emotion regulation in couples: an fNIRS hyperscanning study[J]. Cerebral Cortex, 2023, 12: 12.[8]DREW P J. Neurovascular coupling: motive unknown[J]. Trends in Neurosciences, 2022, 45(11): 809-819.[9]范宇雄, 生物医学工程. 四通道近红外采集系统及实验验证研究[D]. 电子科技大学,2021. FAN Y X, Biomedical Engineering. Research on a Four-Channel Near-Infrared Acquisition System and Experimental Verification [D]. University of Electronic Science and Technology of China, 2021.[10]AASTED C M, YUCEL M A, COOPER R J, et al. Anatomical guidance for functional near-infrared spectroscopy: AtlasViewer tutorial[J]. Neurophotonics, 2015, 2(2): 020801.[11]WEAVER D K, Third Method of Generation and Detection of Single-Sideband Signals[J]. Proceedings of the IRE, 1957, 44(12): 1703-1705.[12]MA Z F, ZHANG C X, ZHANG Z Y, YAN T Y, Signal-Noise Ratio in Optical Heterodyne Detection[J]. Acta Optica Sinica, 2007, 27(5): 889-892.[13]FANTINI?S,SASSAROLI A. FrequencyDomain Techniques for Cerebral and Functional NearInfrared Spectroscopy. Frontiers in Neuroscience. 2020;14:300. [14]SAFI D, LASSONDE M, NGUYEN D K, et al. Functional near‐infrared spectroscopy for the assessment of overt reading[J]. Brain and Behavior, 2012, 2(6): 825-837.[15]洪向前. 频域近红外光谱医用检测系统的研究[D]. 西安:西安电子科技大学硕士学位论文, 2016: 1-26HONG X Q. Research on Medical Detection System of Near-Infrared Spectroscopy in Frequency Domain [D]. Xi'an: Master's Thesis of Xidian University, 2016: 1-26[16]ZHOU X, XIA Y J, UCHITEL J, et al. Review of recent advances in frequencydomain nearinfrared spectroscopy technologies, Biomedical Optics Express.2023 Jun 12;14(7):3234-3258.[17]DELPY D T, Cope M, ZEE P V D, WRAY S, et al.Estimation of optical path length through tissue from direct time of flight measurement Physics in Medicine and Biology, 1988 Dec;33(12):1433-42.[18]Boas D A, FRANCESCHINI M A. Haemoglobin oxygen saturation as a biomarker: The problem and a solution, Philos Trans A Math Phys Eng Sci,2011 Nov 28;369:4407-24 |