J4 ›› 2014, Vol. 31 ›› Issue (2): 222-225.

• Laser Applications • Previous Articles     Next Articles

Influence of Sintering Temperature on Hydroxyapatite Target

LUO Le JIANG Dapeng ZHAO Duliang YAN Zhongya CHENG Guangcun FANG Xiaodong TAO Ruhua   

  1. 1 Electronics and Applied Physics School, Hefei University of Technology, Hefei 230009, China; 2 Department of Cardiac Surgery, Anhui Provincial Hospital, Hefei 230001, China; 3 Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, Hefei 230031
  • Received:2013-08-19 Revised:2013-11-10 Published:2014-03-28 Online:2014-03-20

Abstract: In order to find out rule for sintering temperature to influence hydroxyapatite(HA) target, the powder of 99% pure hydroxyapatite was pressed to discal targets and the targets were sintered at 600℃, 700℃ and 800℃ in argon ambience respectively. The targets stinered at different temperature and the targets not sintered were detected with X-ray diffractometer(XRD) and the X-ray photoelectron spectroscopy(XPS). The experimental result demonstrates sintering temperature did not influence on the composition and crystallinity of all kinds of targets observably, but the average particle diameter and the ratio of Ca to P of hydroxyapatite targets should increase if sintering temperature rised. The hydroxyapatite target sintered at 800℃ should have the best biocompatibility, bioactivity and stability.

Key words: materials, hydroxyapatite target, sintering temperature, ratio of Ca to P, crystallinity, average particle diameter

CLC Number: