Chinese Journal of Quantum Electronics ›› 2020, Vol. 37 ›› Issue (6): 641-649.

• Basic Optics • Previous Articles     Next Articles

Determination of refractive index of capsule by using white light interference techniques

FAN Ting 1,2, MA Xiaojun 2, WANG Zongwei 2, WANG Qi 2, HE Zhibing 2, YI Yong   

  1. 1 School of Materials Science and Engineering, Southwest University of Science and Technology, Mianyang 621010, China; 2 Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900, China
  • Received:2020-04-13 Revised:2020-07-12 Published:2020-11-28 Online:2020-11-28

Abstract: In order to accurately determine the refractive index of capsule, a method for measuring the refractive index of capsules is established based on the combination of white light vertical scanning interference (VSI) and white light reflectance spectra (WLRS). To solve the problems such as the difficulty to accurately determinate the peak positions and the possible interference order error in white reflectance spectra, the data processing method, in which the curve fitting is used to determine the peak positions and the interference order is determined by the continuity of interference order, is applied. The measurement, experimental verification and uncertainty analysis of the refractive index of glass capsule are carried out. It is shown that the refractive index of capsule can be measured accurately by white light interference technique, and the measurement uncertainty is about 0.86%.

Key words: thin film optics, refractive index, white light vertical scanning interference, white light reflectance spectra, capsule

CLC Number: