量子电子学报 ›› 2025, Vol. 42 ›› Issue (3): 324-333.doi: 10.3969/j.issn.1007-5461.2025.03.004

• 光谱 • 上一篇    下一篇

长光程A字型甲烷传感器气室的研究

房 村, 禹胜林*, 滕雪松   

  1. 南京信息工程大学电子与信息工程学院, 江苏 南京 210000
  • 收稿日期:2024-08-26 修回日期:2024-11-15 出版日期:2025-05-28 发布日期:2025-05-28
  • 通讯作者: E-mail: yslhz112@163.com E-mail:E-mail: yslhz112@163.com
  • 作者简介:房 村 ( 1998 - ), 江苏徐州人, 研究生, 主要从事气体传感器方面的研究。 E-mail: fcun825@163.com
  • 基金资助:
    新一代超低浓度颗粒物检测、计量设备关键技术研发 (2019h519)

Long optical⁃path A⁃type gas chamber for methane sensor

FANG Cun, YU Shenglin*, TENG Xuesong   

  1. School of Electronics and Information Engineering, Nanjing University of Information Science & Technology, Nanjing 210000, China
  • Received:2024-08-26 Revised:2024-11-15 Published:2025-05-28 Online:2025-05-28

摘要: 红外气室是非分光红外甲烷传感器的重要组成部分, 它直接影响传感器的性能。本研究基于朗伯-比尔定 律, 设计了一种反射式A字型气室结构, 并通过仿真, 调整优化了气室参数。与直射式气室相比, 在体积和外轮廓参 数相同的情况下, 反射式A字型气室的光程大约是直射式气室光程的两倍; 与现有长光程反射式气室相比, 虽然反射 式A字型气室的光程-面积比改变不大, 但其光通量利用率提高了57.827%。总之, 本研究设计的新型气室弥补了传 统直射式气室光程短的缺点和已有反射式气室光通量利用率低的问题, 同时兼具光程长和光通量利用率高的优点。

关键词: 光谱学, 非分光甲烷传感器, 光学气室, 朗伯-比尔定律, 光程-面积, 光通量利用率

Abstract: Infrared gas chamber is an essential part of a non-dispersive infrared methane sensor and directly affects the performance of the sensor. In this study, based on the Lambert-Beer law, a reflective Atype gas chamber was designed, and the corresponding parameters of the gas chamber were optimized by simulation. Compared with the direct gas chamber, the optical-path length of the reflective A-type chamber is about twice that of the direct gas chamber with the same volume and outline. And compared with the existing reflective chambers, although there is no significant difference about the optical-path length-to-area ratio, the luminous flux utilisation efficiency of the reflective A-type chamber is increased by 57.827%. Overall, the new gas chamber designed in this study compensates for the short optical-path length of the traditional direct gas chamber and the low luminous flux utilisation efficiency of the existing reflective gas chamber, and has the advantages of long optical-path and high luminous flux utilisation efficiency.

Key words: spectroscopy, non-dispersive methane sensor, optical gas chamber, Lambert-Beer law, optical-path-area, luminous flux utilisation efficiency

中图分类号: